The following 10 points are the correct ways to maintain high-precision constant temperature and humidity air conditioners. 1. Dust on the condenser will cause the compressor high-pressure switch to trip and generate false alarms. Therefore, you can use a vacuum cleaner to remove the dust attached to the condenser heat dissipation mesh every month, or use a hard brush to brush it after turning on the machine, or use a high-pressure air nozzle to blow the dust clean.

The following 10 points are the correct ways to maintain high-precision constant temperature and humidity air conditioners.
1. Dust on the condenser will cause the compressor high-pressure switch to trip and generate false alarms. Therefore, you can use a vacuum cleaner to remove the dust attached to the condenser heat dissipation mesh every month, or use a hard brush to brush it after turning on the machine, or use a high-pressure air nozzle to blow the dust clean.
2. The ground around and at the bottom of the high-precision constant temperature and humidity air conditioner should be kept clean at all times to avoid a large amount of dust being sucked into the unit to cause accidents or reduce equipment performance.
3. When opening and closing the door or taking samples from the test chamber, do not let them touch the sealing strip on the door.
4. Check the core of the constant temperature and humidity chamber - the refrigeration system once a year, check whether the copper pipe is leaking, and whether there is any leakage at each joint and interface. If so, please notify the manufacturer.
5. The humidifier and water tank should be cleaned frequently to avoid scale and affect the dissipation of steam. Generally, they are cleaned once after each test. Timely removal of scale is conducive to extending the life of the humidifier tube and ensuring smooth water flow. Use a copper brush to wash and then clean with water.
6. The distribution room should be cleaned and repaired at least once a year. Loose nodes will put the entire equipment in a dangerous working state, which may burn components or cause fire, alarm and life safety.
7. Check the wet and dry ball gauze of high-precision constant temperature and humidity air conditioners frequently. When the gauze becomes hard or dirty, replace it in time. It is recommended to replace it every 3 months.
8. Inspection and maintenance of water pipes Water pipes are easy to block and leak. Please check regularly for leaks and blockages. If there are any, please eliminate them in time or notify the manufacturer.
9. The water storage in the humidifier should be replaced once a month to ensure clean water and smooth water flow.
10 When the test product time is reached, the product must be taken out when the machine is turned off and the staff must wear dry, anti-electric, and moisture-resistant gloves to take and put the product.
The above are the correct methods for maintaining high-precision constant temperature and humidity air conditioners. I hope it will be helpful to you.