What is the use of high-precision constant temperature and humidity air conditioning in the inter-row and inter-column computer room?
Release time:
2020-02-13
As the heat dissipation of the servers or communication equipment used in the data center is increasing, the traditional air conditioning and refrigeration methods can no longer meet the equipment's requirements for humidity and temperature. In order to achieve high-efficiency cooling of the equipment and avoid local overheating, cold air must be organized to enter the equipment for heat dissipation. At this time, the use of cold and hot channel isolation or closed cold and hot channels can effectively control the short circuit of cold air and hot air, thereby reducing the cooling effect.
As the heat dissipation of the servers or communication equipment used in the data center is increasing, the traditional air conditioning and refrigeration methods can no longer meet the equipment's requirements for humidity and temperature. In order to achieve high-efficiency cooling of the equipment and avoid local overheating, cold air must be organized to enter the equipment for heat dissipation. At this time, the use of cold and hot channel isolation or closed cold and hot channels can effectively control the short circuit of cold air and hot air, thereby reducing the cooling effect.
The design of the high-precision constant temperature and humidity air conditioner for the inter-row and inter-column base station is a horizontal air supply method in which the cold air is supplied from the cold channel and then returned by the hot channel. This method completely solves the problem of short circuit of cold and hot air flows, ensures the uniformity of the temperature of the server cabinet, eliminates local hot spots, and thus increases the operating reliability of the server while effectively reducing unnecessary consumption. The
high-precision constant temperature and humidity air conditioners for the inter-row and inter-column computer rooms include chilled water inter-row cooling single coil horizontal air supply, chilled water inter-row cooling double coil horizontal air supply units and direct expansion air-cooled inter-row cooling units. The cooling capacity is 10-48KW, which can provide high-precision constant temperature and humidity air conditioning solutions for data centers with high heat dissipation density under different application environment conditions.
Here is the title one h1 placeholder text
More news