Common problems with high-pressure alarms in high-precision constant temperature and humidity air conditioners
High-precision constant temperature and humidity air conditioner low power supply voltage does not start often due to voltage reduction or phase loss, low power supply voltage, resulting in insufficient output voltage of 24v transformer; 24v AC contactor in condenser cannot work. Specific needs to be tested and determined with a multimeter. If necessary, a power grid voltage stabilizer is equipped.
12
2020
/
03
How to correctly choose high-precision constant temperature and humidity air conditioner for computer room
The high-precision constant temperature and humidity air conditioner for computer rooms has the following characteristics: large air volume, small enthalpy difference, high sensible heat ratio; the heat load of the computer room varies greatly, usually between 10% and 20%; there are various ways of sending and returning air, including upper air supply, lower air supply, upper return air, lower return air, side return air, etc., and the commonly used ones are upper delivery and lower return and lower delivery and upper return; the reliability is high, and the control system and functions of the high-precision constant temperature and humidity air conditioner for computer rooms are much more complete than those of general comfort air conditioners; the reliability of operation throughout the year and all-weather operation.
02
Maintenance of high-precision constant temperature and humidity air conditioners for computer rooms
Maintenance content of high-precision constant temperature and humidity air conditioner for computer room: First, maintenance and maintenance of high-precision constant temperature and humidity air handling unit for computer room
19
What is the use of high-precision constant temperature and humidity air conditioning in the inter-row and inter-column computer room?
As the heat dissipation of the servers or communication equipment used in the data center is increasing, the traditional air conditioning and refrigeration methods can no longer meet the equipment's requirements for humidity and temperature. In order to achieve high-efficiency cooling of the equipment and avoid local overheating, cold air must be organized to enter the equipment for heat dissipation. At this time, the use of cold and hot channel isolation or closed cold and hot channels can effectively control the short circuit of cold air and hot air, thereby reducing the cooling effect.
13
Eight points to note when installing high-precision constant temperature and humidity air conditioners
Whether it is a large or medium-sized computer or a program-controlled switch, the air conditioner is required to operate for cooling all year round. And the cooling operation in winter needs to solve the problem of stable condensing pressure and other related issues.
20