Maintenance of high-precision constant temperature and humidity air conditioners for computer rooms
Maintenance content of high-precision constant temperature and humidity air conditioner for computer room: First, maintenance and maintenance of high-precision constant temperature and humidity air handling unit for computer room
19
2020
/
02
What is the use of high-precision constant temperature and humidity air conditioning in the inter-row and inter-column computer room?
As the heat dissipation of the servers or communication equipment used in the data center is increasing, the traditional air conditioning and refrigeration methods can no longer meet the equipment's requirements for humidity and temperature. In order to achieve high-efficiency cooling of the equipment and avoid local overheating, cold air must be organized to enter the equipment for heat dissipation. At this time, the use of cold and hot channel isolation or closed cold and hot channels can effectively control the short circuit of cold air and hot air, thereby reducing the cooling effect.
13
Eight points to note when installing high-precision constant temperature and humidity air conditioners
Whether it is a large or medium-sized computer or a program-controlled switch, the air conditioner is required to operate for cooling all year round. And the cooling operation in winter needs to solve the problem of stable condensing pressure and other related issues.
20
2019
12
How to choose high-precision constant temperature and humidity air conditioner for laboratory
The constant temperature and humidity laboratory is a place with special requirements. How to maintain the constant temperature and humidity of the laboratory must be completed by using high-precision constant temperature and humidity air conditioners. So what are the selection requirements for constant temperature and humidity laboratory air conditioning equipment?
How to clean a high-precision constant temperature and humidity air conditioner
Although the equipment and pipelines in the high-precision constant temperature and humidity air conditioning refrigeration system are rust-removed and cleaned before installation, welding slag, oxide scale and other debris will be generated during the welding process of the installation pipeline. If not cleaned, the valve core will be damaged, the expansion valve and filter will be blocked, and the cylinder will become rough, making the system unable to work properly. Therefore, before the trial run, the cleaning work should be carried out carefully.